Bioquell L-2

Bioquell L-2

The Bioquell L-2 is a second generation hydrogen peroxide vapor (HPV) generator, replacing Bioquell’s widely used Clarus L HPV generator.

The Bioquell L-2 offers enhanced functionality and is able to bio-decontaminate both enclosures and rooms/laboratories up to 75m3. The Bioquell L-2 has enhanced HPV delivery and control, as well as an improved user interface using touch screen controls.

Download the Bioquell Clarus L-2 brochure

Make an enquiry

> Larger preview

Features

  • Accurate measurement of the amount of hydrogen peroxide vaporized
  • Simple menu-driven user interface to set cycle parameters and access to bio-decontamination parameters
  • Graphical display of bio-decontamination cycle progress tracking critical parameters in real time
  • Communications port allows integration to building management system (BMS) or related systems and equipment
  • Data logging option allowing data export into Excel® format
  • Multiple language options
  • Bioquell dual circuit technology for fast and efficient bio-decontamination cycles
  • No requirement for room dehumidification prior to cycles

Benefits

  • Minimal process downtime – no need for preconditioning, process operates with ambient environment
  • Can bio-decontaminate rooms and enclosures up to 75m3.
  • Small footprint requiring minimal floor space
  • Compatible with GMP and GLP requirements
  • Simple integration into a building management system (BMS) or the Bioquell PORT rapid decontamination transfer chamber

Technical

 

Materials of external construction Top moulding – polypropylene
Side panels – polyurethane coated aluminium
Temperature
Operating
Storage

15°C to 35°C
15°C to 50°C
Relative humidity
Operating
Storage
 
75% RH maximum
95% RH (non-condensing)
Power requirement  AC 220 – 240V 50 Hz (Euro) 6 amps
AC 110 – 120V 60 Hz (USA) 12 amps
AC 90 – 110V 50/60 Hz (Japan) 12 amps
Power consumption 1300W
Power supply Installation category II
Operating position Upright only
Pollution degree environment 2
Dimensions (WxHxD) 515 x 1140 x 705mm
Weight 80 kg
Maximum H2O2 liquid volume 1 liter
H2O2 liquid concentration 30-35% w/w Bioquell hydrogen peroxide (stored at 2-8°C)
Hose pipes 1.5 inch nominal bore
Gas hose connections male/female
Camlock fittings 1.5 inch
 
Control system Siemens® S7 PLC (GAMP compliant software)
Airflow rate
Gassing
Conditioning/aeration
 
 
Controlled at 25 m3/hr
Controlled at 25 m3/hr at 750Pa external pressure
Temperature of supply gas at outlet  75°C maximum
 
H2O2 liquid injection rate 1.5 to 6 g/min (gassing); 0 or 1.5 to 6 g/min (dwell)
Refrigeration system off coil temperature Approx 2°C (from 20°C return)
Condensate removal Evaporation to atmosphere
Inlet air HEPA filter efficacy 99.997%
Gassing & dehum circuit HEPA filter efficacy 99.997%
Pressurization system flow rate 100 l/min (max)
Pressurization system range +200 to -200 Pa
Noise Less than 60 dBA at 1 metre (free field)


Approvals Information

MET Registration Approval Mark MET Certification record  Download MET Certificate
CE Certificate Download CE certificate
 
EMC Testing
 
EMC Certificate  
Download EMC certificate
 

    